Weidmuller WI-I/O-EX: Wireless I/O Expansion Modules v1.11 User Manual

Browse online or download User Manual for Hardware Weidmuller WI-I/O-EX: Wireless I/O Expansion Modules v1.11. Weidmuller WI-I/O-EX: Wireless I/O Expansion Modules v1.11 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 55
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Weidmuller Inc., 821 Southlake Blvd., Richmond, VA 23236
Tel: (800) 849-9343 Fax: (804) 897-4136 Email: [email protected]
Web: www.weidmuller.com
User Manual
WI-I/O-EX Serial I/O Module
Page view 0
1 2 3 4 5 6 ... 54 55

Summary of Contents

Page 1 - User Manual

Weidmuller Inc., 821 Southlake Blvd., Richmond, VA 23236 Tel: (800) 849-9343 Fax: (804) 897-4136 Email: [email protected] Web: www.weidmull

Page 2 - Important Notice

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 10 February 2010 2 Installation All connections to the module should be SELV only. Normal

Page 3

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 11 You can connect to an WI-GTWY-9-MD1 Module using either MODBUS prot

Page 4 - 1 Overview

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 12 February 2010 2.2 Signal Connections All connections to the module should be SELV onl

Page 5

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 13 2.2.2 Digital Outputs (and Pulsed Outputs) The WI-I/O-EX-1-S-11 s

Page 6

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 14 February 2010 2.2.3.1 Grounded Single-Ended mA Inputs Single-ended current inputs allow

Page 7

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 15 2.2.3.2 Floating Differential Mode mA Inputs Differential mode cu

Page 8

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 16 February 2010 2.2.3.3 Floating Differential Voltage Inputs Differential voltage inputs

Page 9

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 17 2.2.3.4 Single-ended Voltage Input Single-ended voltage inputs all

Page 10 - 2 Installation

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 18 February 2010 2.2.4.1 Current Output Current output mode may be configured for current

Page 11

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 19 Note: - The hardware configuration needs to be changed for this ty

Page 12

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 2 February 2010 Thank you for your selection of the WI-I/O-EX Serial I/O Module. We trust

Page 13

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 20 February 2010 3 Configuration Use the WI Series Configuration utility to configure th

Page 14

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 21 Figure 3-1: Configuration of WI-I/O-EX modules using Configurati

Page 15

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 22 February 2010 Finally, you will be prompted to select the module address. You can choo

Page 16

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 23 4 Hardware Configuration Hardware Set-up allows the WI-I/O-EX h

Page 17 - Sensor with voltage

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 24 February 2010 • Set the “Port” setting to match the computer com port you have connecte

Page 18

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 25 Note that you will need to change the connection settings on the “

Page 19

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 26 February 2010 4.3 WI-I/O-EX-11 configuration 4.3.1 Pulsed Inputs Choose the Pulse Inp

Page 20 - 3 Configuration

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 27 4.4 WI-I/O-EX-12 configuration 4.4.1 Voltage input Voltage input

Page 21

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 28 February 2010 4.4.1.1 Single-ended voltage input If the WI-I/O-EX-1-S-12 is to measure

Page 22

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 29 4.4.1.2 Differential voltage input The WI-I/O-EX-1-S-12 can be con

Page 23 - 4 Hardware Configuration

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 3 CONTENTS 1 OVERVIEW ...

Page 24

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 30 February 2010 Clicking Read from WI-I/O-EX will read the scales out of the unit (if any

Page 25

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 31 4.4.2.1 Single-ended current input The WI-I/O-EX-1-S-12 can also m

Page 26

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 32 February 2010 4.4.2.2 Differential current input The WI-I/O-EX-1-S-12 can be configure

Page 27

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 33 Choose the desired scale for each channel in the Scale box. Click t

Page 28

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 34 February 2010 To configure the WI-I/O-EX-1-S-13 for voltage output, select the page as s

Page 29

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 35 4.5.2 Current output Current outputs may be selected in the scal

Page 30

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 36 February 2010 To configure the WI-I/O-EX-1-S-13 for current output, select the page as s

Page 31

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 37 5 Operation 5.1 WI-I/O-EX-11 module The I/O terminal block for th

Page 32

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 38 February 2010 Figure 5-2: Check the operation of the WI-I/O-EX-11 module using the DIO

Page 33

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 39 5.2 WI-I/O-EX-1-S-12 module The I/O terminal block for the WI-I/O-

Page 34

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 4 February 2010 APPENDIX E. RS232 WIRING ...

Page 35

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 40 February 2010 Digital inputs are reflected in the software by blacking (ON) or greying

Page 36

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 41 Figure 5-6: Check the operation of the WI-I/O-EX-1-S-13 module us

Page 37 - 5 Operation

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 42 February 2010 5.4 Hexadecimal representation of voltage and current levels The voltage

Page 38

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 43 Appendix A. ModBus address map A.1. WI-I/O-EX-11 Data ModBus I/O

Page 39

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 44 February 2010 Data ModBus I/O Type ModBus Addresses Pulse input rate 3 Input register

Page 40

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 45 A.2. WI-I/O-EX-1-S-12 Data ModBus I/O Type ModBus Addresses Digi

Page 41

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 46 February 2010 Data ModBus I/O Type ModBus Addresses Analog inputs 2 Input registers

Page 42

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 47 A.3. WI-I/O-EX-1-S-13 Data ModBus I/O Type ModBus Addresses Digi

Page 43

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 48 February 2010 Data ModBus I/O Type ModBus Addresses Analog outputs 1 Holding register

Page 44 - 0x4000 = 8V; 0xC000 = 16V

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 49 Appendix B. ModBus Functionality Table B-1 specifies the maximum

Page 45

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 5 Figure 1-1: WI-I/O-EX unit with significant parts labele

Page 46 - 0x4000 =12V; 0xC000 = 36V

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 50 February 2010 Appendix C. Comms Recovery If the communications setting of the WI-I/O-EX

Page 47

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 51 Address Description 40201 Serial port transmission mode 40202 Se

Page 48

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 52 February 2010 11. Once the new comms setting are correct, be sure to change the address

Page 49

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 53 Appendix D. Specifications EMC Approval EN 55024:1998 EN 61000-3-

Page 50 - Appendix C. Comms Recovery

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 54 February 2010 On-state voltage <2.1VDC Wetting current 5mA Max pulse input rat

Page 51

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 55 Appendix E. RS232 Wiring The RS232 connection to the WI-I/O-EX mo

Page 52

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 6 February 2010 WI-I/O-EX -11 -12 -13 Digital inputs/outputs Up to 16 Up to 8 Up to 8

Page 53 - Appendix D. Specifications

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 7 to reach the Target within the update time. The output pulse rate is

Page 54

WI-I/O-EX Serial I/O Module User Manual v1.11 Page 8 February 2010 The two types of input cannot be mixed - all inputs must be either “grounde

Page 55 - Appendix E. RS232 Wiring

WI-I/O-EX Serial I/O Module User Manual v1.11 WI-IO-EX Manual v1.11 Page 9 1.1.6 Communications The WI-I/O-EX modules have two communication p

Comments to this Manuals